Southwire 26020050-1 Description

Shockshield in-line GFCI ensures protection from dangerous current leakage that can cause electrical shock and possible electrocution.

Southwire 26020050-1 Includes

  • (1) Cord

Southwire 26020050-1 Features

  • GFCI with 4-6mA trip point
  • 25mS trip response time
  • Manual reset
  • Provides compliance with NEC 2008 Article 590.6 for Temporary Installations
  • Custom cable gauges, lengths and terminations available by special order

Southwire 26020050-1 Specifications

Voltage 120V
Cord Length 50'
Amps 15A
NEMA 5-15 P&R, Black
Grounded Neutral 4 Ohms
Trip Response Time for Ground Fault and Grounded Neutral Trip Less Than 25mS
Radio Frequency Noise Susceptibility Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz
Effect of 10 Amp Turn DC Shock Fault Trip 5% Maximum Trip Level Variation on Ground
Endurance 3,000 Operations Minimum
Overload Current Six Times Rated Current
Insulation Voltage 1500 Vrms - 1 Min.
Cord Gauge 14/3 AWG
Applications Include High Pressure Sprayer Washers, Construction Site Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances
$41.25

Original: $117.86

-65%
Southwire 26020050-1 50' 120V/15A 14/3 Gauge SJTW GFCI In-Line Cord Set, Yellow Color (26020M)

$117.86

$41.25

Product Information

Shipping & Returns

Description

Southwire 26020050-1 Description

Shockshield in-line GFCI ensures protection from dangerous current leakage that can cause electrical shock and possible electrocution.

Southwire 26020050-1 Includes

  • (1) Cord

Southwire 26020050-1 Features

  • GFCI with 4-6mA trip point
  • 25mS trip response time
  • Manual reset
  • Provides compliance with NEC 2008 Article 590.6 for Temporary Installations
  • Custom cable gauges, lengths and terminations available by special order

Southwire 26020050-1 Specifications

Voltage 120V
Cord Length 50'
Amps 15A
NEMA 5-15 P&R, Black
Grounded Neutral 4 Ohms
Trip Response Time for Ground Fault and Grounded Neutral Trip Less Than 25mS
Radio Frequency Noise Susceptibility Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz
Effect of 10 Amp Turn DC Shock Fault Trip 5% Maximum Trip Level Variation on Ground
Endurance 3,000 Operations Minimum
Overload Current Six Times Rated Current
Insulation Voltage 1500 Vrms - 1 Min.
Cord Gauge 14/3 AWG
Applications Include High Pressure Sprayer Washers, Construction Site Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances